In the field of electrical engineering, norms and standards play an important role. Thus, electrical machinery and equipment must be thoroughly inspected for compliance with local standards as well as application-specific standards before commissioning. Concerning power supply, the Underwriter Laboratories (UL) and the CSA are responsible for defining and publishing the relevant norms and standards for the North American market. These are used to test and certify the safety of a large number of products in a wide variety of sectors. The certificates are used in many parts of the world beyond the North American continent. In addition to electrification, UL standards are also significant in numerous other areas, such as equipment safety or fire protection. GREMCO offers cables and wires certified with UL types for the field of electrical engineering.
In the electrical engineering sector, a distinction must be made between three classic fields of UL certification:
The NEC area primarily includes UL types for the standardization of wires and cables. Of decisive importance here is the National Electrical Code (NEC), which defines the place and type of application of the respective cables. The area of the National Fire Protection Association (NFPA) includes standards for the legally compliant installation of electronic equipment. This includes the requirements that it must meet in terms of design, wiring, grounding, operation, labeling, and testing in order to comply with fire protection standards, for example.
The classic UL area primarily describes the areas of UL-Appliance Wire Material (UL-AWM) and UL types. UL types are the identifying code on the cable that provides information on the product designation and the UL-certified core properties of the cable. Thus, UL types cover the standardization of products for power supply from transformer or socket to the end device. UL Appliance Wire Material, in turn, covers the certification of components associated with the inner workings of an electronic device.
GREMCO offers a wide range of UL-certified cables and wires. Depending on performance, the field of application, and material, these can in turn be divided into different categories. For example, the ULAWM-1007 stranded cable, made of PVC, is characterized by high flexibility, temperature resistance up to 80°C, voltage tolerance up to 300V, and excellent price-performance ratio. With high flexibility, at very high performance under voltage up to 1000V, the single-core UL-AWM 10721 made of TPF is again suitable for usage according to UL-AWM Style Page Subj. 758 Internal wiring. In the tables below, an overview of GREMCO’s UL-certified cables and wires, sorted by their core properties, is attached.
High flexibility / low cost | material | temperature | voltage |
UL 1007 | PVC | 80 ° C. | 300V |
UL 1662 | PVC | 80 ° C. | 300V |
UL 1015 | PVC | 105 ° C. | 600V |
UL 1032 | PVC | 90 ° C. | 1000V |
High flexibility / high performance | |||
UL 10720 | TPE | 105 ° C. | 300V |
UL 10721 | TPE | 105 ° C. | 1000V |
High temperature / high flexibility | |||
UL 3132 | Silikon | 150 ° C. | 300V |
UL 3123 | Silikon | 150 ° C. | 600V |
UL 3214 | Silikon | 150 ° C. | 600V |
High temperature / thin sleeve | |||
UL 1716 | FEP, PFA | 150 ° C. | 150V |
UL 10326 | PFA | 200 ° C. | 150V |
UL 10315 | ETFE | 125 ° C. | 300V |
UL 10316 | ETFE | 125 ° C. | 600V |
UL 10313 | FEP, PFA | 200 ° C. | 600 |
We would be pleased to advise you on our product range and the possible applications of the Fitcoflex woven hose polyethylene. Please contact us!
Would you like more information about our company and our products? Simply fill out the following contact form completely and send it to us. One of our responsible experts will get back to you as soon as possible.
However, you are also welcome to contact us by phone at any time on
+49 (0)821 27 26 3-01. We are available for you!
Thank you for your message!
Your request has reached us. We will contact you as soon as possible! In urgent cases, we are of course also available for you at any time at
+49 (0)821 27 26 3-01!
Sie Besuchen unsere Englische Website.
Möchten Sie lieber auf Deutsch wechseln?
We need your consent before you can continue to visit our website. If you are under 16 and wish to give your consent to volunteer services, you must ask your parent or guardian for permission. We use cookies and other technologies on our website. Some of them are essential, while others help us improve this website and your experience. Personal data may be processed (e.g. IP addresses), e.g. for personalized ads and content or ad and content measurement. For more information about how we use your data, please see our Privacy Policy. You can revoke or adjust your selection at any time under preferences.
If you are under 16 and wish to give your consent to volunteer services, you must ask your parent or guardian for permission. We use cookies and other technologies on our website. Some of them are essential, while others help us improve this website and your experience. Personal data may be processed (e.g. IP addresses), e.g. for personalized ads and content or ad and content measurement. For more information about how we use your data, please see our Privacy Policy. You can revoke or adjust your selection at any time under preferences. Here you can find an overview of all cookies used. You can give your consent to entire categories or view more information and thus select only certain cookies.